SPARC® EnterpriseM4000/M5000 ServersProduct NotesFor XCP version 1050Manual Code C120-E481-01ENPart No. 820-3264-10September 2007, Revision A

Seite 2

x SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 2007

Seite 3

1SPARC Enterprise M4000/M5000 Servers Product NotesThese product notes contain late-breaking information about the SPARC® Enterprise M4000/M5000 ser

Seite 4

2 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 2007Note – When the XCP version preinstalled in your server is u

Seite 5 - Contents

SPARC Enterprise M4000/M5000 Servers Product Notes 3Known IssuesThis section describes known issues in this release.General Functionality Issues and

Seite 6

4 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 2007 The target board (SB/XSB) with optional I/O cards because

Seite 7 - Software Resources

SPARC Enterprise M4000/M5000 Servers Product Notes 5Hardware Installation and Service IssuesThis section describes hardware specific issues and work

Seite 8 - Accessing Documentation

6 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 2007Cautions for mounting the server in the 19-inch rack When yo

Seite 9 - Preface ix

SPARC Enterprise M4000/M5000 Servers Product Notes 72. In place of the removed nut and ring, attach the E-Ring, included in the rack mount kit.3. In

Seite 10

8 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 2007Hardware Documentation UpdatesTABLE 2 lists known documentat

Seite 11 - Servers Product Notes

SPARC Enterprise M4000/M5000 Servers Product Notes 9SPARC Enterprise M4000/M5000 Servers Service Manual4-11 4.4.3, "Powering the Server Off Man

Seite 12 - Patch Information

PleaseRecycleCopyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. and FUJITSU LIMITED, 1-1, Kamikodanaka

Seite 13 - Known Issues

10 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 2007Electrical SpecificationsThe following changes belong in th

Seite 14 - Notes for XSCF Web

SPARC Enterprise M4000/M5000 Servers Product Notes 11Cable ConnectionsThe following changes belong in the SPARC Enterprise M4000/M5000 Servers Insta

Seite 15 - CR ID Description Workaround

12 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 2007Updates of the SPARC Enterprise M4000/M5000 Servers Service

Seite 16 - Ring Bezel Anchoring nut

SPARC Enterprise M4000/M5000 Servers Product Notes 13DIMM ReplacementThe DIMMs are cold FRU replacement components. The entire server must be powere

Seite 17

14 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 2007Here are the DIMM mount conditions: In each group, 4 DIMMs

Seite 18 - Documentation Updates

SPARC Enterprise M4000/M5000 Servers Product Notes 15Software IssuesThis section describes software specific issues and workarounds.XCP Issues and W

Seite 19 - Title Page Number Update

16 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 2007RTIF1-070418-025showaudit all shows a long list of defaults

Seite 20 - Electrical Specifications

SPARC Enterprise M4000/M5000 Servers Product Notes 17RTIF1-070824-004On the XSCF Web, on the Domain Status screen, when you select an XSB displayed

Seite 21 - Cable Connections

18 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 2007RTIF1-070904-003An incorrect domain state is reported. Afte

Seite 22 - Installing the PCI Cassette

SPARC Enterprise M4000/M5000 Servers Product Notes 19RTIF1-070914-005On the XSCF Web, when using Internet Explorer 7, on the User Accounts screen, U

Seite 23 - DIMM Replacement

Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. et FUJITSU LIMITED, 1-1, Kamikodanaka 4-chome, Nakah

Seite 24

20 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 2007RTIF1-070914-012On the XSCF Web, on the SNMP-Properties scr

Seite 25 - Software Issues

SPARC Enterprise M4000/M5000 Servers Product Notes 21RTIF1-070914-019When you use a user account which is not the user account when you performed th

Seite 26 - ID Description Workaround

22 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 2007Solaris Issues and WorkaroundsTABLE 6 lists known issues an

Seite 27

SPARC Enterprise M4000/M5000 Servers Product Notes 236466617 Performing a hot plug operation with the PCI-Express slot too quickly interrupts a PCI

Seite 28

24 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 20076496337 The "cpumem-diagnosis" module may fail to

Seite 29

SPARC Enterprise M4000/M5000 Servers Product Notes 256502204 Unexpected error messages may be displayed on console on booting after CPU UE panic.Exa

Seite 30

26 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 20076515648 "Replumb Failed" error appears when dr@0:

Seite 31

SPARC Enterprise M4000/M5000 Servers Product Notes 276527811 showhardconf(8) on XSCF can not display PCI card information that is installed in Exter

Seite 32

28 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 20076535564 PCI hot plug to PCI slot #0, #1 or External IO Expa

Seite 33

SPARC Enterprise M4000/M5000 Servers Product Notes 296545685 If the following message displayed on the OS console, memory degradation or XSB deconfi

Seite 35

30 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 20076559504 Messages of the form nxge: NOTICE: nxge_ipp_eccue_v

Seite 36

SPARC Enterprise M4000/M5000 Servers Product Notes 31Identifying Permanent Memory in a Target Board 1. Log in to XSCF. 2. Execute the following comm

Seite 37 - (at Solaris prompt)

32 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 2007Upgrading to XCP 1050Note – By upgrading to XCP 1050, XSCFU

Seite 38

SPARC Enterprise M4000/M5000 Servers Product Notes 337. Upload the XCP 1050 upgrade image by using the command line getflashimage.The BUI on XSCFU#0

Seite 39

34 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 200713. Wait until XSCF firmware reaches the ready state.This c

Seite 40

SPARC Enterprise M4000/M5000 Servers Product Notes 3519. Confirm that both the current and reserve banks of XSCFU#1 display the updated XCP versions

Seite 41

36 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 2007b. Confirm switching over between XSCFs using the following

Seite 42 - Upgrading to XCP 1050

SPARC Enterprise M4000/M5000 Servers Product Notes 37Software Documentation UpdatesThis section contains late-breaking software information that bec

Seite 43

38 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 2007

Seite 44 - XSCF> showlogs event

v ContentsPreface viiTechnical Support viiSoftware Resources viiAccessing Documentation viiiFujitsu Welcomes Your Comments ixSPARC Enterprise M4000/M5

Seite 45

vi SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 2007 Updates of the SPARC Enterprise M4000/M5000 Servers Servic

Seite 46

viiPrefaceThese product notes contain late-breaking information about the SPARC® Enterprise M4000/M5000 server hardware, software, or documentation th

Seite 47

viii SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 • September 2007Note – For latest patch information go to: Global Sitehtt

Seite 48

Preface ixFujitsu Welcomes Your CommentsIf you have any comments or requests regarding this manual, or if you find any unclear statements in the manua

Kommentare zu diesen Handbüchern

Keine Kommentare